Features

 
Extreme VDX 6740 Top of Rack (ToR) switches support 1/10/40 GbE ports—enabling the efficiency and flexibility you need to support cloud computing, virtualization, mobility, and consolidation.
 

Specifications

Specifications

  • VDX 6740
  • Form Factor 1U
  • Switching bandwidth (data rate, full duplex) 1.28 Tbps
  • Switch performance 960 Mpps
  • Port-to-port latency 850 ns
  • Dimensions and weight Width: 43.99 cm (17.32 in.)
  • Height: 4.32 cm (1.75 in.)
  • Depth: 40.99 cm (16.14 in.)
  • Weight: 8.66 kg (19.1 lb)
  • 10 GbE SFP+ ports Up to 64
  • 162/4/8/16 Gbps Fibre Channel Flex Ports Up to 32 (out of 64 10 GbE ports)Port types supported: E_Port (connecting to EX_Port only), F_Port, N_Port (Access Gateway mode)
  • 1/10 GBASE-T 0
  • 40 GbE QSFP+ (10 GbE breakout cable) 4
  • 10 GbE Ports on Demand (PoD) 24, 32, 40, 48, 56, 64
  • 10 GbE Capacity on Demand (CoD) N/A
  • Power supplies Two hot-swappable, load-sharing
  • Cooling fans N+1 redundant, integrated into power supplies
  • Airflow Front to back Back to front
  • Connector Options Out-of-band Ethernet management: RJ45 (fixed) Console management: RJ45 to RS-232 (fixed) Firmware and diagnostic: USB
  • Maximum VLANs 4,096
  • Maximum MAC addresses 160,000
  • Maximum port profiles (AMPP) 1,024
  • Maximum members in a standard LAG 64
  • Maximum per-port priority pause level 8
  • Maximum switches that a vLAG can span 8
  • Maximum members in a vLAG 64
  • Maximum jumbo frame size 9,216 bytes
  • Queues per port 8
  • DCB Priority Flow Control (PFC) classes 8
  • Maximum ACLs 13,000
  • Maximum ARP entries 32,000
  • Maximum IPv4 unicast routes 12,000
  • Maximum IPv6 unicast routes 3,000
  • HA/ISSU ISSU fully supported
  • Enclosure Front-to-rear, rear-to-front airflow; 1U, 19-inch EIA-compliant; power from non-port side
  • Temperature Operating: 0°C to 40°C (32°F to 104°F) Non-operating and storage: -25°C to 70°C (-13°F to 158°F)
  • Humidity Operating: 10% to 85% non-condensing Non-operating and storage: 10% to 90% non-condensing
  • Altitude Operating: Up to 3,048 meters (10,000 feet) Non-operating and storage: Up to 12 kilometers (39,370 feet)
  • Shock Operating: 20 G, 11 ms half-sine Non-operating and storage: Square wave, 44 G, 15 ms
  • Vibration Operating: 0.5 G peak, 0.7 G ms random, 5 to 500 Hz Non-operating and storage: 2.0 g sine, 1.4 G rms random, 5 to 500 Hz
  • Airflow VDX 6740T port-side-intake: Maximum: 49.3 CFM; Nominal: 26.3 CFMB VDX 6740T port-side-exhaust: Maximum: 51.9 CFM; Nominal: 27.3 CFM VDX 6740 port-side-intake and port-side-exhaust: Maximum: 25.7 CFM; Nominal: 11.5 CFM
  • Heat dissipation 1,672.41 BTU/hr
  • Power supplies Two internal, redundant, field-replaceable, load-sharing AC power supplies
  • Power inlet C13
  • Input voltage 85 to 264 VAC nominal
  • Input line frequency 50 to 60 Hz
  • Inrush current Limited to 30 A peak at 240 VAC during cold startup at 25°C ambient
  • Maximum current 6 A max at 100 VAC/60 Hz
  • Maximum power consumption VDX 6740: 110 W VDX 6740T: 460 W VDX 6740T-1G: 276 W (Base SKU)
  • CAN/CSA C22.2 No. 60950-1-07 including A1 / UL 60950-1-07, Ed. 2 including A1 User Datagram Protocol (UDP)
  • CAN/CSA-C22.2 No. 60950-1 Second Edition TFTP Protocol (revision 2)
  • EN 60950-1 Second Edition +A1/A12 Internet Protocol (IP)
  • IEC 60950-1 Second Edition +A1•GB 4943.1-2011 and GB9254-2008 Internet Control Message Protocol (ICMP)
  • CNS14336-1(99) Transmission Control Protocol (TCP)
  • FCC Class A ARP
  • ICES-003 Class A Telnet Protocol Specification
  • VCCI-Class A A Standard for the Transmission of IP Datagram over Ethernet Networks
  • CE FTP
  • C-Tick Using ARP to Implement Transparent Subnet Gateways (Proxy ARP)
  • BSMI IGMPv1
  • GOST Simple Network Management Protocol (SNMP) v1 and v2
  • KCC Class A Network Time Protocol (NTP) Version 3
  • CCC TACACS+
  • ANSI C63.4 Classless Inter-Domain Routing (CIDR)
  • ICES-003 Class A Multicast Extensions to OSPF
  • CISPR22 and JEIDA (Harmonics) OSPF Database Overflow
  • EN55022 Class A and EN55024 Requirements for IP Version 4 Routers
  • CISPR22 BGP Communities Attribute
  • AS/NZS CISPR22 HTTP Server
  • CNS 13438(95) Dynamic Host Configuration Protocol (DHCP)
  • 51318.22-99 and 51318.24-99 OSPF with Digital Signatures (Password, MD-5)
  • KN22 and KN24 IGMPv2
  • GB17625.1-2003 Network Ingress Filtering
  • RoHS-6 (with lead exemption) Directive 2002/95/EC OSPF v2
  • VDX 6740 products conform to the following Ethernet standards: OSPF Opaque Link-State Advertisement (LSA) Option—Partial Support
  • IEEE 802.1D Spanning Tree Protocol IPv6 Multicast Address Assignments
  • IEEE 802.1s Multiple Spanning Tree Protection of BGP Sessions with the TCP MD5 Signature Option
  • IEEE 802.1w Rapid Reconfiguration of Spanning Tree Protocol BGP Route Flap Damping
  • IEEE 802.3 Ethernet Internet Protocol, Version 6 (v6) Specification (on management interface)
  • IEEE 802.3ad Link Aggregation with LACP IPv6 Stateless Address Auto-Configuration
  • IEEE 802.3ae 10G Ethernet Transmission of IPv6 Packets over Ethernet Networks (on management interface)
  • IEEE 802.1Q VLAN Tagging Definition of the Differentiated Services Field in the IPv4 and IPv6 Headers
  • IEEE 802.1p Class of Service Prioritization and Tagging An Architecture for Describing SNMP Management Frameworks
  • IEEE 802.1v VLAN Classification by Protocol and Port IPv6 Router Alert Option
  • IEEE 802.1AB Link Layer Discovery Protocol (LLDP) Remote Authentication Dial-In User Service (RADIUS)
  • IEEE 802.3x Flow Control (Pause Frames) The OSPF Not-So-Stubby Area (NSSA) Option
  • IEEE 802.3ab 1000BASE-T OSPF Stub Router Advertisement
  • IEEE 802.3z 1000BASE-X sFlow
  • The following draft versions of the Data Center Bridging (DCB) and Fibre Channel over Ethernet (FCoE) standards are also supported on the VDX 6740: Capabilities Advertisement with BGPv4
  • IEEE 802.1Qbb Priority-based Flow Control An Architecture for Describing SNMP Frameworks
  • IEEE 802.1Qaz Enhanced Transmission Selection Message Processing and Dispatching for the SNMP
  • IEEE 802.1 DCB Capability Exchange Protocol (Proposed under the DCB Task Group of IEEE 802.1 Working Group) Simple Network Management Protocol (SNMP) Applications
  • FC-BB-5 FCoE (Rev 2.0) IPv6 Global Unicast Address Format
  • The VDX 6740 products conform to the following Fibre Channel standards: Graceful OSPF Restart—IETF Tools
  • FC-GS-5 ANSI INCITS 427:2007 (includes the following) –FC-GS-4 ANSI INCITS 387: 2004 VRRP
  • FC-SP-2 INCITS 496-2012(AUTH-A, AUTH-B1 only) BGPv4
  • FC-DA INCITS TR-36: 2004 (includes the following) –FC-FLA INCITS TR-20: 1998–FC-PLDA INCIT S TR-19: 1998 IPv6 Addressing Architecture
  • FC-MI-2 ANSI/INCITS TR-39-2005 IP Forwarding MIB
  • FC-PI INCITS 352: 2002 Management Information Base for the Internet Protocol (IP)
  • FC-PI-2 INCITS 404: 2005 ICMPv6 (replaces 2463)
  • FC-PI-4 INCITS 1647-D, revision 7.1 (under development) BGP Route Reflection
  • FC-FS-2 ANSI/INCITS 424:2006 (includes the following) –FC-FS INCITS 373: 2003 Lightweight Directory Access Protocol (LDAP): Technical Specification Road Map
  • FC-LS INCITS 433: 2007 Protocol Independent Multicast—Sparse Mode (PIM-SM): Protocol Specification (Revised)
  • MIB-FA INCITS TR-32: 2003 Graceful Restart Mechanism for BGP
  • RFC 768 IPv6 Neighbor Discovery
  • RFC 783 BGP Support for Four-Octet AS Number Space
  • RFC 791 Generalized TTL Security Mechanism (GTSM)
  • RFC 792 Bidirectional Forwarding Detection (BFD)
  • RFC 793 Bidirectional Forwarding Detection (BFD) for IPv4 and IPv6 (Single Hop)
  • RFC 826 Generic Application of Bidirectional Forwarding Detection (BFD)
  • RFC 854 Bidirectional Forwarding Detection (BFD) for Multihop Paths
  • RFC 894 IPv6 Neighbor Discovery
  • RFC 959 BGP-EVPN—Network Virtualization Using VXLAN Data Plane
  • RFC 1027
  • RFC 1112 Use of BGP-MP Extensions for IPv6
  • RFC 1157 OSPFv3 for IPv6
  • RFC 1305
  • RFC 1492 Multicast Listener Discovery (MLD) for IPv6
  • RFC 1519
  • RFC 1584 VRRP Version 3 for IPv4 and IPv6
  • RFC 1765
  • RFC 1812 Maximum switches in a fabric
  • RFC 1997 Maximum ECMP paths in a fabric
  • RFC 2068 Maximum LAGs in a fabric
  • RFC 2131 Service Node Load Balancing BFD/ARP Optimizations
  • RFC 2154 Conversational MAC Learning
  • RFC 2236 Virtual Link Aggregation Group (vLAG) spanning
  • RFC 2267 Layer 2 Access Control Lists (ACLs)
  • RFC 2328 Supports 2K ingress and egress ACLs
  • RFC 2370 Edge Loop Detection (ELD)
  • RFC 2375 Address Resolution Protocol (ARP) RFC 826
  • RFC 2385 Private VLANs
  • RFC 2439 Maintenance Mode/Graceful Traffic Diversion
  • RFC 2460 Distributed VXLAN Gateway
  • RFC 2462 Diagnostic Ports
  • RFC 2464 IP Maps Support
  • RFC 2474 L2 Loop prevention in an overlay environment
  • RFC 2571 High availability/In-Service Software Upgrade—hardware-enabled
  • RFC 2711 IGMP snooping support for multicast flooding
  • RFC 2865 IGMPv1/v2 Snooping
  • RFC 3101 IGMPv1/v2 Snooping
  • RFC 3137 IGMPv3
  • RFC 3176 MAC Learning and Aging
  • RFC 3392 Link Aggregation Control Protocol (LACP) IEEE 802.3ad/802.1AX
  • RFC 3411 Virtual Local Area Networks (VLANs)
  • RFC 3412 VLAN Encapsulation 802.1Q
  • RFC 3413 Per-VLAN Spanning Tree (PVST+/PVRST+)
  • RFC 3587 Rapid Spanning Tree Protocol (RSTP) 802.1w
  • RFC 3623 Multiple Spanning Tree Protocol (MSTP) 802.1s
  • RFC 3768 STP PortFast, BPDU Guard, BPDU Filter
  • RFC 4271 STP Root Guard
  • RFC 4291 Pause Frames 802.3x
  • RFC 4292 Static MAC Configuration
  • RFC 4293 Uni-Directional Link Detection (UDLD)
  • RFC 4443 Uplink switch for VDX switches, VCS fabrics, and the VCS Virtual Fabric feature
  • RFC 4456 Transparent LAN Services
  • RFC 4510 L2 Traceroute for VXLAN
  • RFC 4601 BUM Storm Control
  • RFC 4724 Border Gateway Protocol (BGP4+)
  • RFC 4861 DHCP Helper
  • RFC 4893 Layer 3 ACLs
  • RFC 5082 Multicast: PIM-SM, IGMPv2
  • RFC 5880 OSPF v2/v3
  • RFC 5881 Static routes
  • RFC 5882 IPv4/v6 ACL
  • RFC 5883 IPv4/v6 ACL
  • RFC 5942 Policy-Based Routing (PBR)
  • RFC 7432 Bidirectional Forwarding Detection (BFD)
  • IPv6 Routing 32-Way ECMP
  • RFC 2545 VRF Lite
  • RFC 2740 VRF-aware OSPF, BGP, VRRP, static routes
  • IPv6 Multicast VRRP v2 and v3
  • RFC 2710 uRPF for IPv4 and IPv6
  • VRRP/VRRPe IPv4/IPv6 dual stack
  • RFC 5798 IPv6 ACL packet filtering
  • BGP automatic neighbor discovery for IP fabric
  • Software scalability BGP Additional-Path
  • BGP-Allow AS
  • BGP Generalized TTL Security Mechanism (GTSM)
  • Layer 2 switching BGP graceful shutdown for maintenance mode
  • BGP Peer Auto Shutdown
  • Multicast Refactoring
  • IPv6 routing
  • OSPF Type-3 LSA Filter
  • Wire-speed routing for IPv4 and IPv6 using any routing protocol
  • BGP-EVPN Control Plane Signaling RFC 7432
  • BGP-EVPN VXLAN Standard-based Overlay
  • Multi-VRF
  • IP Unnumbered Interface
  • Intersubnet Routing (Symmetric and Asymmetric)
  • IP over Port Channel
  • VRRP-E
  • Fabric Virtual Gateway
  • Static Anycast Gateway
  • ARP Suppression
  • OpenFlow 1.3
  • REST API with YANG data model
  • Puppet
  • Python
  • PyNOS libraries
  • VMware vRealize plugins
  • DHCP automatic fabric provisioning
  • Netconf API
  • TRILL FGL-based VCS Virtual Fabric feature
  • Virtual fabric extension
  • VM-Aware Network Automation
  • BFD for virtual fabric extension
  • Automatic Migration of Port Profiles (AMPP)
  • Priority-based Flow Control (PFC) 802.1Qbb
  • Enhanced Transmission Selection (ETS) 802.1Qaz
  • Manual configuration of lossless queues for protocols other than FCoE and iSCSI
  • Data Center Bridging Exchange (DCBX)
  • DCBX Application Type-Length-Value (TLV) for FCoE and iSCSI
  • Layer 3 switching Multi-hop Fibre Channel over Ethernet (FCoE); requires VCS Fabric technology
  • FC-BB5 compliant Fibre Channel Forwarder (FCF)
  • Native FCoE forwarding
  • FCoE to Fibre Channel Bridging
  • FCoE on VDX 8770
  • FCoE on QSFP+ port
  • Multi-hop Access Gateway Support
  • End-to-end FCoE (initiator to target)
  • FCoE Initialization Protocol (FIP) v1 support for FCoE device login and initialization
  • Name Server-based zoning
  • Supports connectivity to FIP Snooping Bridge (FSB) device
  • FCoE traffic over standard LAG
  • Interface Binding
  • Dual Personality Ports
  • Logical SANs
  • ISSU L2 and L3
  • BFD
  • OSPF3-NSR
  • BGP4-GR
  • Management Module Failover
  • ACL-based QoS
  • Eight priority levels for QoS
  • Class of Service (CoS) IEEE 802.1p
  • DSCP Trust
  • DSCP to Traffic Class Mutation
  • DSCP to CoS Mutation
  • DSCP to DSCP Mutation
  • Random Early Discard
  • Per-port QoS configuration
  • ACL-based Rate Limit
  • Dual-rate, three-color token bucket
  • ACL-based remarking of CoS/DSCP/Precedence
  • ACL-based sFlow
  • Scheduling: Strict Priority (SP), Deficit Weighted Round-Robin (DWRR), Hybrid Scheduling (Hybrid)
  • Queue-based Shaping
  • Flow-based QoS
  • Logical chassis management
  • Automation and programmability IPv4/IPv6 management
  • Industry-standard Command Line Interface (CLI)
  • Netconf API
  • REST API with YANG data model
  • VDX Plugin for OpenStack
  • Link Layer Discovery Protocol (LLDP) IEEE 802.1AB
  • MIB II RFC 1213 MIB
  • Switch Beaconing
  • Mulititenancy and virtualization Management VRF
  • Switched Port Analyzer (SPAN)
  • Telnet
  • SNMP v1, v2C, v3
  • sFlow RFC 3176
  • DCB
  • Out-of-band management
  • Remote SPAN (RSPAN)
  • RMON-1, RMON-2
  • NTP
  • Fibre Channel/FCoE Management Access Control Lists (ACLs)
  • Role-Based Access Control (RBAC)
  • Range CLI support
  • UDLD
  • OpenStack Neutron ML2 plugin
  • Python
  • Puppet
  • Distributed Configuration Management
  • Maps switch health monitoring
  • Port-based Network Access Control 802.1X
  • RADIUS (AAA)
  • TACACS+
  • Secure Shell (SSHv2)
  • BPDU Drop X X
  • Lightweight Directory Access Protocol (LDAP)
  • High availability Secure Copy Protocol
  • Port Security
  • VDX 6740, 24P SFP+ ports only—no optics, AC, non-port-side exhaust airflow
  • VDX 6740, 24P SFP+ ports only—no optics, AC, port-side exhaust airflow
  • VDX 6740, 48P SFP+ ports only—no optics, AC, non-port-side exhaust airflow
  • Quality of Service (QoS) VDX 6740, 48P SFP+ ports only—no optics, AC, port-side exhaust airflow
  • VDX 6740, 64P SFP+ ports only—no optics, AC, non-port-side exhaust airflow
  • VDX 6740, 64P SFP+ ports only—no optics, AC, port-side exhaust airflow
  • VDX 6740, 64P SFP+ ports only—no optics, AC, FCoE, VCS fabric, non-port-side exhaust airflow
  • VDX 6740, 64P SFP+ ports only—no optics, AC, FCoE, VCS fabric, port-side exhaust airflow
  • VDX 6740T, 24P 10GBASE-T ports only—no optics, AC, non-port-side exhaust airflow
  • VDX 6740T, 24P 10GBASE-T ports only—no optics, AC, port-side exhaust airflow
  • VDX 6740T, 48P 10GBASE-T ports only—no optics, AC, non-port-side exhaust airflow
  • VDX 6740T, 48P 10GBASE-T ports only—no optics, AC, port-side exhaust airflow
  • VDX 6740T, 48P 10GBASE-T and 4 SFP+ ports only—no optics, AC, non-port-side exhaust airflow
  • VDX 6740T, 48P 10GBASE-T and 4 SFP+ ports only—no optics, AC, port-side exhaust airflow
  • VDX 6740T, 48P 10GBASE-T and 4 SFP+ ports only—no optics, AC, FCoE, VCS fabric, non-port-side exhaust airflow
  • VDX 6740T, 48P 10GBASE-T and 4 SFP+ ports only—no optics, AC, FCoE, VCS fabric, port-side exhaust airflow
  • VDX 6740T-1G, 48P 1000BASE-T and 2 40 GbE QSFP+ ports, upgradable to 10GBASE-T via license only—no optics, AC, non-port-side exhaust airflow
  • VDX 6740T-1G, 48P 1000BASE-T and 2 40 GbE QSFP+ ports, upgradable to 10GBASE-T via license only—no optics, AC, port-side exhaust airflow
  • 8-port PoD license for VDX 6740 and 6740T
  • Management and monitoring 2-port 40 GbE PoD license for VDX 6740 and 6740T
  • 16-port 1 GbE to 10 GbE Capacity on Demand (CoD) upgrade license for VDX 6740T-1G
  • Software, FCoE license for VDX 6740 and 6740T
  • Software, VCS license for VDX 6740 and 6740T
  • Software, VCS and FCoE license for VDX 6740 and 6740T
  • FRU 250 W AC power supply/fan, non-port-side exhaust airflow, VDX 6740
  • FRU 250 W AC power supply/fan, port-side exhaust airflow, VDX 6740
  • FRU 500 W AC power supply/fan, non-port-side exhaust airflow, VDX 6740T, 6740T-1G
  • FRU 500 W AC power supply/fan, port-side exhaust airflow, VDX 6740T, 6740T-1G
  • AN-FAC fan, non-port-side exhaust airflow, VDX 6740T, 6740T-1G
  • AC fan, port-side exhaust airflow, VDX 6740T, 6740T-1G
  • FRU, VDX 6740 fixed rack-mount kit for 4-post racks
  • FRU, VDX 6740 mid-mount kit for 2-post racks
  • Flush-mount kit for 2-post racks for VDX 6740
  • FRU, universal 2-post mid-mount kit/flush-mount kit, VDX 6740T/6740T-1G
  • FRU, universal rack-mount kit, 4-post, 24- to 32-inch depth rack, VDX 6740T/6740T-1G
  • URL
 