InRow 30kW Condensing Unit, 480V, Single feed
Close-coupled, air, water, and glycol cooling for closets, server rooms, and data centers
Includes: Installation guide, Integrated network management, Network Management Card, User Manual
Active Airflow Control
Monitors and actively adjust cooling unit airflow in containment systems, while providing visibility to effective cooling to critical IT equipment.
Active response control
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.
Air filtration
Removes dirt and other particulates from the intake air for cleaner supply air.
Architecturally neutral
Unobtrusive design and coloring, blends in with the surroundings.
Capacity Control
Cooling system will operate from 0 - 100% of the rated capacity to maintain rack inlet temperatures and reduce operational costs at varying heat loads.
Casters
Provides flexibility to move the unit to wherever cooling is required.
Containment system compatible
The unit can be combined with a Rack or Hot Aisle Containment System to eliminate hot air mixing and maximize cooling efficiency
Continuous current monitoring
Permits a continuous monitoring of the compressor’s absorbed current to signal possible discrepancies with the default values (Optional).
Direct drive motors
Stress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.
Ease of Use
Simplifies future planning by allowing side to side equipment to be placed anywhere in the data center.
Easy to install
Innovative design allows for fast, easy installation by almost anybody.
Efficiency
Increases the capacity of the air conditioner by supplying a warmer return air temperature.
Electronic expansion valve
Refrigerant flow optimization at any load and temperature conditions. Continuous indirect refrigerant charge monitoring
Electronically Commutated Fans
Provide the highest efficiency and reduce total power consumption by matching the airflow requirements to the heat load of the data center.
Enclosure system compatible
Specifically designed to work with Netshelter Enclosures.
Fan guards
A safety measure that provides protection from the fan opening by covering the inlet.
Fault-tolerant fan system
In the event of a fan failure, the remaining fan(s) will continue to operate.
Field replaceable components
Fans and electronics module can be readily replaced without uninstalling the unit.
Flexibility
Support for varying aisle widths, rack heights, rack depths, and single rows. Supports hot and cold aisle containment
Front service access
The system has full service, front access for routine servicing of components. Front access also narrows the footprint of the system making it possible for units to be placed side by side.
Green Refrigerant
Environmentally friendly refrigerant that can offer LEED points.
High Sensible-to-Total Cooling Ratio
Achieved by careful sizing of heat exchanger coils.
Horizontal airflow pattern
Removes heat close to the source of generation in the hot aisle and distributes cold air to the front of the racks in the cold aisle.
Increased capacity
Higher rate of heat removal allows more equipment to be installed in each rack.
Local area network
Creates a shared control between all the available resources for maximum energy efficiency and controlled management of the group during emergency situations
Minimizes Air Mixing
Delivers cool, conditioned air directly to the inlet of IT equipment.
Modular strategy
Modular design of the mechanical and control systems allow for gradual build-up of the cooling infrastructure to match the cooling demand of the facility. This greatly reduces CAPEX expediture and provides deferred investment throughout the life of the facility.
Network interface
Provides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.
Operational efficiency
Warmer entering air temperatures reduce both the required amount of humidification and the demand for costly reheat.
Scalable Design
Modular design provides scalable solutions to add cooling as demand increases.
Small Footprint
Efficient use of space with a small footprint provides the ability for the unit to be placed in a corner or even installed into a partitioned space.
Specifications
Specifications
Easy service accessAllows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
Manageability
Building management system integrationSend alarms and data points allowing you to manage critical building infrastructure from a single system.
Microprocessor controllerUtilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display
Real-Time capacity monitoringReal-time display of current and available cooling.
Availability
Predictable coolingPlacing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Active response controlsMonitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
Rack inlet temperature controlReduces the risk of hot spots at the rack level
Total Cost of Ownership
Row-based architectureCaptures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
Variable speed fansVariable speed fans reduce energy consumption during off-peak cooling periods.
Agility
Scalable densitiesAllows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
Modular designModular design provides scalable solutions to add cooling as demand increases.
Input
Nominal Input Voltage480V 3PH
Input frequency50/60 Hz
Physical
Maximum Height61.2inches
(1554MM, 155.4CM)
Maximum Width39.4inches
(1001MM, 100.1CM)
Maximum Depth39.4inches
(1001MM, 100.1CM)
Net Weight588.6lbs.
(266.98KG)
Shipping weight654.8lbs.
(297.01KG)
Shipping Height68.7inches
(1745MM, 174.5CM)
Shipping Width42.7inches
(1085MM, 108.5CM)
Shipping Depth44.7inches
(1135MM, 113.5CM)
Conformance
ApprovalscUL Listed, UL Listed
Standard warranty1 year on-site repair or replace with factory authorized Start-Up