InRow 30kW Condensing Unit, 480V, Single feed
  • Guaranteed Satisfaction
  • Easy Returns
  • Authorized Reseller
  • Best Practice
$17,800.00

Order Now to ship Tomorrow

OR
Manufacturer Part Number:
ACCU30101
Sku:
ACCU30101

Features

 

ACCU30101 Features

InRow 30kW Condensing Unit, 480V, Single feed Close-coupled, air, water, and glycol cooling for closets, server rooms, and data centers Includes: Installation guide, Integrated network management, Network Management Card, User Manual
 
 

Active Airflow Control

Monitors and actively adjust cooling unit airflow in containment systems, while providing visibility to effective cooling to critical IT equipment.
 
 

Active response control

Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.
 
 

Air filtration

Removes dirt and other particulates from the intake air for cleaner supply air.
 
 

Architecturally neutral

Unobtrusive design and coloring, blends in with the surroundings.
 
 

Capacity Control

Cooling system will operate from 0 - 100% of the rated capacity to maintain rack inlet temperatures and reduce operational costs at varying heat loads.
 
 

Casters

Provides flexibility to move the unit to wherever cooling is required.
 
 

Containment system compatible

The unit can be combined with a Rack or Hot Aisle Containment System to eliminate hot air mixing and maximize cooling efficiency
 
 

Continuous current monitoring

Permits a continuous monitoring of the compressor’s absorbed current to signal possible discrepancies with the default values (Optional).
 
 

Direct drive motors

Stress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.
 
 

Ease of Use

Simplifies future planning by allowing side to side equipment to be placed anywhere in the data center.
 
 

Easy to install

Innovative design allows for fast, easy installation by almost anybody.
 
 

Efficiency

Increases the capacity of the air conditioner by supplying a warmer return air temperature.
 
 

Electronic expansion valve

Refrigerant flow optimization at any load and temperature conditions. Continuous indirect refrigerant charge monitoring
 
 

Electronically Commutated Fans

Provide the highest efficiency and reduce total power consumption by matching the airflow requirements to the heat load of the data center.
 
 

Enclosure system compatible

Specifically designed to work with Netshelter Enclosures.
 
 

Fan guards

A safety measure that provides protection from the fan opening by covering the inlet.
 
 

Fault-tolerant fan system

In the event of a fan failure, the remaining fan(s) will continue to operate.
 
 

Field replaceable components

Fans and electronics module can be readily replaced without uninstalling the unit.
 
 

Flexibility

Support for varying aisle widths, rack heights, rack depths, and single rows. Supports hot and cold aisle containment
 
 

Front service access

The system has full service, front access for routine servicing of components. Front access also narrows the footprint of the system making it possible for units to be placed side by side.
 
 

Green Refrigerant

Environmentally friendly refrigerant that can offer LEED points.
 
 

High Sensible-to-Total Cooling Ratio

Achieved by careful sizing of heat exchanger coils.
 
 

Horizontal airflow pattern

Removes heat close to the source of generation in the hot aisle and distributes cold air to the front of the racks in the cold aisle.
 
 

Increased capacity

Higher rate of heat removal allows more equipment to be installed in each rack.
 
 

Local area network

Creates a shared control between all the available resources for maximum energy efficiency and controlled management of the group during emergency situations
 
 

Minimizes Air Mixing

Delivers cool, conditioned air directly to the inlet of IT equipment.
 
 

Modular strategy

Modular design of the mechanical and control systems allow for gradual build-up of the cooling infrastructure to match the cooling demand of the facility. This greatly reduces CAPEX expediture and provides deferred investment throughout the life of the facility.
 
 

Network interface

Provides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.
 
 

Operational efficiency

Warmer entering air temperatures reduce both the required amount of humidification and the demand for costly reheat.
 
 

Scalable Design

Modular design provides scalable solutions to add cooling as demand increases.
 
 

Small Footprint

Efficient use of space with a small footprint provides the ability for the unit to be placed in a corner or even installed into a partitioned space.
 

Specifications

Specifications

  • Easy service access Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
  • Manageability
  • Building management system integration Send alarms and data points allowing you to manage critical building infrastructure from a single system.
  • Microprocessor controller Utilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display
  • Real-Time capacity monitoring Real-time display of current and available cooling.
  • Availability
  • Predictable cooling Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
  • Active response controls Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
  • Rack inlet temperature control Reduces the risk of hot spots at the rack level
  • Total Cost of Ownership
  • Row-based architecture Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
  • Variable speed fans Variable speed fans reduce energy consumption during off-peak cooling periods.
  • Agility
  • Scalable densities Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
  • Modular design Modular design provides scalable solutions to add cooling as demand increases.
  • Input
  • Nominal Input Voltage 480V 3PH
  • Input frequency 50/60 Hz
  • Physical
  • Maximum Height 61.2inches (1554MM, 155.4CM)
  • Maximum Width 39.4inches (1001MM, 100.1CM)
  • Maximum Depth 39.4inches (1001MM, 100.1CM)
  • Net Weight 588.6lbs. (266.98KG)
  • Shipping weight 654.8lbs. (297.01KG)
  • Shipping Height 68.7inches (1745MM, 174.5CM)
  • Shipping Width 42.7inches (1085MM, 108.5CM)
  • Shipping Depth 44.7inches (1135MM, 113.5CM)
  • Conformance
  • Approvals cUL Listed, UL Listed
  • Standard warranty 1 year on-site repair or replace with factory authorized Start-Up
  • URL
 
  Loading...