Condenser, 46KW, 115F(46C),460V/3, 50/60HZ
Condenser, 46KW, 115F(46C),460V/3, 50/60HZ
Features
ACCD75231 Features
Condenser, 46KW, 115F(46C),460V/3, 50/60HZ
Close-coupled, air, water, and glycol cooling for closets, server rooms, and data centers
Direct drive motors
Stress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.
Specifications
Specifications
-
Easy service access
Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
- Manageability
-
Building management system integration
Send alarms and data points allowing you to manage critical building infrastructure from a single system.
-
Microprocessor controller
Utilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display
-
Real-Time capacity monitoring
Real-time display of current and available cooling.
- Availability
-
Predictable cooling
Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
-
Active response controls
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
-
Rack inlet temperature control
Reduces the risk of hot spots at the rack level
- Total Cost of Ownership
-
Row-based architecture
Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
-
Variable speed fans
Variable speed fans reduce energy consumption during off-peak cooling periods.
- Agility
-
Scalable densities
Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
-
Modular design
Modular design provides scalable solutions to add cooling as demand increases.
- Input
-
Input frequency
50 Hz
-
Input Power
3190.0Watts
-
Maximum Overcurrent Protection
15.0A
-
Minimum Circuit Amp Capacity
8.0
- Physical
-
Maximum Height
32.45inches
(824MM, 82.4CM)
-
Maximum Width
38.48inches
(977MM, 97.7CM)
-
Net Length
10.34ft
(3.16meters)
-
Maximum Depth
124.06inches
(3151MM, 315.1CM)
-
Net Weight
480.0lbs.
(217.72KG)
-
Shipping weight
600.0lbs.
(272.16KG)
-
Shipping Height
35.0inches
(889MM, 88.9CM)
-
Shipping Width
43.0inches
(1092MM, 109.2CM)
-
Shipping Depth
43.0inches
(1092MM, 109.2CM)
- Environmental
-
Operating Temperature
-4 - 122 °F
(-20 - 50 °C)
-
Operating Elevation
0-10000ft
(0-3000meters)
-
Audible noise at 1 meter from surface of unit
64.5dBA
- Conformance
-
Approvals
ETL
-
Standard warranty
1 year (parts only)
-
Proposition 65 Warning
Available in Documentation tab
-
Air Discharge Patterns
Horizontal, Upflow
-
Air Flow
16045.0CFM
(7572.4lps)
-
Amp Draw In-Rush
6.0A
-
Return Diameter
0.87inches
(22.0MM)
-
Supply Diameter
0.63inches
(16.0MM)
-
URL