Water-cooled 460/3/60 Downflow
Perimeter cooling for medium and large data center environments
Specifications
Specifications
Total Cost of Ownership
EconomizationAchieved by utilizing cool ambient air during winter months to take advantage of economizer hours and eliminating compressor operation.
Electronically Commutated FansProvide the highest efficiency and reduce total power consumption by matching the airflow requirements to the heat load of the data center.
Tandem compressorsQuiet and efficient operation of compressors, connected on a common refrigerant circuit for staged capacity control (not available for some models/configuration)
Optimized managementConnection between the Computer Room Air Conditioners and the chillers guarantees energy efficiency, based on real instantaneous load conditions (optional)
Modular strategyModular design of the mechanical and control systems allow for gradual build-up of the cooling infrastructure to match the cooling demand of the facility. This greatly reduces CAPEX expediture and provides deferred investment throughout the life of the facility.
Availability
Active response controlMonitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.
Electronic expansion valveRefrigerant flow optimization at any load and temperature conditions. Continuous indirect refrigerant charge monitoring
Redundant ComponentsSingle points of failure in the system have redundant components to maintain availability and reliability.
Multi-functional Microprocessor ControllerAllows the units to restart after a power failure without intervention; Allows for room level redundancy with up to ten units operating in a group; User friendly navigation with icon based displays to indicate mode of operation as well as room conditions; Allows for communication with multiple Building Management System protocols.
Direct drive motorsStress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.
Energy Management
Network interfaceProvides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.
Local area networkCreates a shared control between all the available resources for maximum energy efficiency and controlled management of the group during emergency situations
Automatic Floor Pressurization SystemEnsures stable airflow pressurization under floor regardless of changes made above the floor
Building Management SystemsUnits are designed to work with the most common BMS systems including BACnet and Modbus.
Serviceability
Service monitoringAll the monitoring devices on board the unit allow for preventive maintenance and a check of the working condition of the system while its in operation.
Operational ServiceAllows critical components to be maintained/replaced while the system is in operation.
Easy service accessAllows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
Input frequency60 Hz
Control panelMulti-function LCD status and control console