APC Smart-UPS RT 5000VA RM 208V to 208/120V
High density, double-conversion on-line power protection with scalable runtime
Includes: CD with software, Rack Mounting support rails, Removable support feet, Smart UPS signalling RS-232 cable, User Manual
Multiple output voltages
48Vdc, 24Vdc, and 120Vac are available to power all of the equipment in the cabinet.
Specifications
Specifications
Key Features
Output power capacity4.0kWatts
/ 5.0kVA
Rack Height3U
Output Connections(4)
NEMA 5-20R
(Battery Backup)
(1)
NEMA L14-30R
(Battery Backup)
(1)
NEMA L6-30R
(Battery Backup)
Nominal Output Voltage120V, 208V
Nominal Input Voltage208V
Input ConnectionsNEMA L14-30P
Cord Length10ft
(3.05meters)
Marketing Features
Save time with easy and convenient remote/network accessibility.Network manageable via serial, USB or Ethernet. Includes Powerchute® Software for convenient monitoring and control, safe operating system shutdown, and innovative energy management capabilities.
Peace of mind that comes with full equipment compatibility and reliability of a leaderProvides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.
Avoids costly power problems by keeping your IT equipment and data protected and available.Network grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.
Low operating and maintenance costs with proven reliability and intelligent battery management.Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down.
Protection
Resettable circuit breakerEasy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
Safety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Frequency and voltage regulationGives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Input power factor correctionMinimizes installation costs by enabling the use of smaller generators and cabling.
Power conditioningProtects connected loads from surges, spikes, lightning, and other power disturbances.
Cold-start capableProvides temporary battery power when the utility power is out.
Generator compatibleEnsures clean, uninterrupted power to protected equipment when generator power is used.
Manageability
LED status indicatorsQuickly understand unit and power status with visual indicators.
Serial connectivityProvides management of the UPS via a serial port.
SmartSlotCustomize UPS capabilities with management cards.
InfraStruXure Manager CompatibleEnables centralized management via the APC InfraStruXure Manager.
Network manageableProvides remote power management of the UPS over the network.
Adaptability
Plug-and-Play external batteriesEnsures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Rack/Tower convertibleProtects the initial investment in the UPS when migrating from tower to rack-mount environment.
Flash upgradeable firmwareInstall maintenance releases of firmware remotely using FTP.
Availability
Automatic restart of loads after UPS shutdownAutomatically starts up the connected equipment upon the return of utility power.
Automatic internal bypassSupplies utility power to the connected loads in the event of a UPS power overload or fault.
Scalable runtimeAllows additional run time to be quickly added as needed.
Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.
Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replaced
Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.
Disconnected battery notificationWarns when a battery is not available to provide backup power.
Audible alarmsProvides notification of changing utility power and UPS power conditions
User-replaceable batteriesIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.
Output
Max Configurable Power (Watts)4.0kWatts
/ 5.0kVA
Output Voltage NoteConfigurable for 208 or 240 nominal output voltage
Efficiency at Full Load90.0 %
Output Voltage DistortionLess than 2%
Output Frequency (sync to mains)50/60 Hz +/- 3 Hz user adjustable +/- 0.1
Other Output Voltages240
Load Crest Factor3 : 1
TopologyDouble Conversion Online
Waveform typeSine wave
BypassInternal Bypass (Automatic and Manual)
Input
Input frequency50/60 Hz +/- 5 Hz (auto sensing)
Input voltage range for main operations156 - 236V
Input voltage adjustable range for mains operation85 - 136V
Number of Power Cords1
Efficiency at Full Load90.0 %
Other Input Voltages240
Batteries & Runtime
Battery typeMaintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Included Battery Modules2
Typical recharge time2.5hour(s)
Replacement BatterySRT192RMBP2US
Expected Battery Life (years)3 - 5
RBC Quantity1
Extendable Run Time1
Battery Volt-Amp-Hour Capacity960
Extended Run OptionsAPC-Smart-UPS-RT-5000VA-RM-208V-to-208-120V
RuntimeView Runtime Graph
View Runtime Chart
Communications & Management
Interface Port(s)RJ-45 10/100 Base-T, SmartSlot
Pre-Installed SmartSlot™ CardsAP9631
Control panelLED status display with load and battery bar-graphs and On Line : On Battery : Replace Battery : Overload and Bypass Indicators
Audible AlarmAlarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Emergency Power Off (EPO)Yes
Surge Protection and Filtering
Surge energy rating365Joules
FilteringFull time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449