APC Smart-UPS RT 6000VA RM 208V to 208/120V
  • Guaranteed Satisfaction
  • Easy Returns
  • Authorized Reseller
  • Best Practice
$7,329.00

Order Now to ship Tomorrow

OR
Manufacturer Part Number:
SURTD6000RMXLP3U
Sku:
SURTD6000RMXLP3U
UPC:
731304258827

Features

 

SURTD6000RMXLP3U Features

APC Smart-UPS RT 6000VA RM 208V to 208/120V High density, double-conversion on-line power protection with scalable runtime Includes: CD with software, Rack Mounting support rails, Removable support feet, Smart UPS signalling RS-232 cable, User Manual
 
 

Multiple output voltages

48Vdc, 24Vdc, and 120Vac are available to power all of the equipment in the cabinet.
 

Specifications

Specifications

  • Key Features
  • Output power capacity 4.2kWatts / 6.0kVA
  • Rack Height 3U
  • Output Connections (1) NEMA L6-30R (Battery Backup) (1) NEMA L14-30R (Battery Backup) (4) NEMA 5-20R (Battery Backup)
  • Nominal Output Voltage 120V, 208V
  • Nominal Input Voltage 208V
  • Input Connections NEMA L14-30P
  • Cord Length 10ft (3.05meters)
  • Marketing Features
  • Save time with easy and convenient remote/network accessibility. Network manageable via serial, USB or Ethernet. Includes Powerchute® Software for convenient monitoring and control, safe operating system shutdown, and innovative energy management capabilities.
  • Peace of mind that comes with full equipment compatibility and reliability of a leader Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.
  • Avoids costly power problems by keeping your IT equipment and data protected and available. Network grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.
  • Low operating and maintenance costs with proven reliability and intelligent battery management. Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down.
  • Protection
  • Resettable circuit breaker Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
  • Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
  • Frequency and voltage regulation Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
  • Input power factor correction Minimizes installation costs by enabling the use of smaller generators and cabling.
  • Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances.
  • Cold-start capable Provides temporary battery power when the utility power is out.
  • Generator compatible Ensures clean, uninterrupted power to protected equipment when generator power is used.
  • Manageability
  • LED status indicators Quickly understand unit and power status with visual indicators.
  • Serial connectivity Provides management of the UPS via a serial port.
  • SmartSlot Customize UPS capabilities with management cards.
  • InfraStruXure Manager Compatible Enables centralized management via the APC InfraStruXure Manager.
  • Network manageable Provides remote power management of the UPS over the network.
  • Adaptability
  • Plug-and-Play external batteries Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
  • Rack/Tower convertible Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
  • Flash upgradeable firmware Install maintenance releases of firmware remotely using FTP.
  • Availability
  • Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power.
  • Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS power overload or fault.
  • Scalable runtime Allows additional run time to be quickly added as needed.
  • Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging.
  • Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
  • Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature.
  • Serviceability
  • Predictive failure notification. Provides early-warning fault analysis ensuring proactive component replacement.
  • Disconnected battery notification Warns when a battery is not available to provide backup power.
  • Audible alarms Provides notification of changing utility power and UPS power conditions
  • User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
  • Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Output
  • Max Configurable Power (Watts) 4.2kWatts / 6.0kVA
  • Output Voltage Note Configurable for 208 or 240 nominal output voltage
  • Efficiency at Full Load 90.0 %
  • Output Voltage Distortion Less than 2%
  • Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz user adjustable +/- 0.1
  • Other Output Voltages 240
  • Load Crest Factor 3 : 1
  • Topology Double Conversion Online
  • Waveform type Sine wave
  • Bypass Internal Bypass (Automatic and Manual)
  • Input
  • Input frequency 50/60 Hz +/- 5 Hz (auto sensing)
  • Input voltage range for main operations 156 - 236V
  • Input voltage adjustable range for mains operation 85 - 136V
  • Number of Power Cords 1
  • Efficiency at Full Load 90.0 %
  • Other Input Voltages 240
  • Batteries & Runtime
  • Battery type Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
  • Included Battery Modules 2
  • Typical recharge time 2.5hour(s)
  • Replacement Battery APCRBC140
  • Expected Battery Life (years) 3 - 5
  • RBC Quantity 1
  • Extendable Run Time 1
  • Battery Volt-Amp-Hour Capacity 960
  • Extended Run Options APC-Smart-UPS-RT-6000VA-RM-208V-to-208-120V
  • Runtime View Runtime Graph View Runtime Chart
  • Communications & Management
  • Interface Port(s) RJ-45 10/100 Base-T, SmartSlot
  • Pre-Installed SmartSlot™ Cards AP9631
  • Control panel LED status display with load and battery bar-graphs and On Line : On Battery : Replace Battery : Overload and Bypass Indicators
  • Audible Alarm Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
  • Emergency Power Off (EPO) Yes
  • Surge Protection and Filtering
  • Surge energy rating 480Joules
  • Filtering Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449
  • Physical
  • Maximum Height 5.1inches (130MM, 13.0CM)
  • Maximum Width 17.0inches (432MM, 43.2CM)
  • Maximum Depth 26.0inches (660MM, 66.0CM)
  • Net Weight 127.73lbs. (58.06KG)
  • Shipping weight 158.66lbs. (72.12KG)
  • Shipping Height 13.68inches (347MM, 34.7CM)
  • Shipping Width 23.73inches (603MM, 60.3CM)
  • Shipping Depth 38.6inches (980MM, 98.0CM)
  • Color Black
  • Units per Pallet 6.0
  • Environmental
  • Operating Temperature 32 - 104 °F (0 - 40 °C)
  • Operating Relative Humidity 0 - 95 (non-condensing) %
  • Operating Elevation 0-10000ft (0-3000meters)
  • Storage Temperature -15 - 45 °C
  • Storage Relative Humidity 0 - 95 (non-condensing) %
  • Storage Elevation 0-50000ft (0-15000meters)
  • Audible noise at 1 meter from surface of unit 55.0dBA
  • Online thermal dissipation 1780.0BTU/hr
  • Protection Class IP 20
  • Conformance
  • Approvals CSA, FCC Part 15 Class A, UL 1778
  • Standard warranty 2 years repair or replace
  • Sustainable Offer Status
  • RoHS Compliant
  • REACH REACH: Contains No SVHCs
  • PEP Available in Documentation tab
  • EOLI Available in Documentation tab
  • Battery Directive Compliant
  • Proposition 65 Warning Available in Documentation tab
  • URL
 