Servertech Smart POPS CSG-24V2/E 3.3kW - 7.3kW (18) C13 & (6) C19 outlets Rack PDU - CSG-24V2A415A1
  • Guaranteed Satisfaction
  • Easy Returns
  • Authorized Reseller
  • Best Practice
Call for price

Order Now to ship Tomorrow

OR
Manufacturer Part Number:
CSG-24V2A415A1
Sku:
CSG-24V2A415A1
The Server Technology® Smart POPS PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® and POPS® technology provides accurate measurement of current (billing-grade), voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input and at each output. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The Smart POPS “Master" PDU can be connected to a Smart POPS “Link" PDUs to extend the network access to the redundant or secondary power feed.

Features

 

Network Monitoring

Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
 
 

Linkable Expansion

Connect an Expansion rack PDU to a Master rack PDU for power monitoring of separate power circuits from a single IP address.
 
 

Temperature/ Humidity Monitoring

Master and Link (select products) units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications.
 
 

Auto-Flip Current Display

Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets.
 
 

Per-Inlet Power Sensing

Meets ANSI C12.1 for billing-grade accuracy of Current per phase. PIPS includes voltage, active power, apparent power, power factor, and energy.
 
 

Per-Outlet Power Sensing

Meets ANSI C12.1 for billing-grade accuracy of Current per phase. POPS includes voltage, active power, apparent power, power factor, and energy.
 
 

Branch Circuit Protection

This rack PDU meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses.
 
 

High Retention Locking Outlets

Receptacles have high retention and are compatible with P-Lock type power cords.
 
 

Flexible Mounting

This rack PDU includes standard button mounts along with provisions for custom mounting brackets (contact Server Technology for details).
 
 

Color Identification

Choose from six colors to designate circuits for rack PDUs in the data center. Color options include Blue, Red, Green, White, Yellow, and Black.
 

Specifications

Specifications

  • Family Specifications
  • Branch Monitoring Sense
  • Branch Overcurrent Protection 5 kAIC
  • Branch Overcurrent Protection Type Circuit Breaker: 2-pole
  • Dual Input No
  • High Retention Outlets Yes
  • Input Current Display Auto-Orient
  • Input Monitoring PIPS
  • Locking Outlets Yes
  • Max Operating Temperature 50 °C
  • Fast Movers No
  • Mounting 0U Vertical
  • Outlet Monitoring POPS
  • PDU Platform CDU1
  • Power Pivot Input No
  • Product Height (inch) 61.0
  • Product Height (mm) 1550
  • Product Max Depth (inch) 3.5
  • Product Max Depth (mm) 89
  • Product Nominal Depth (inch) 3.5
  • Product Nominal Depth (mm) 89
  • Product Width (inch) 1.75
  • Product Width (mm) 45
  • Product Specifications
  • Input Power Capacity (kW) 3.3
  • Input Plug Type IEC C20 200-240V Inlet
  • Input Current (A) 20
  • Input Current Rated (A) 16
  • Input Nominal Voltage (V) 208
  • Input Phase 1-Phase (L-L)
  • Input Cord Location Bottom/Front
  • Outlet Form Factor Conventional
  • Total Outlets 24
  • IEC C13 Count 18
  • IEC C19 Count 6