Servertech PRO2â„¢ Smart POPS C2SG24VT 5.7KW-8.6KW 3-PH (18) C13 & (6) C19 outlets Rack PDU - STV-5542L
  • Guaranteed Satisfaction
  • Easy Returns
  • Authorized Reseller
  • Best Practice
Call for price

Order Now to ship Tomorrow

OR
Manufacturer Part Number:
STV-5542L
Sku:
STV-5542L
The Server Technology® PRO2 Smart POPS PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® and POPS® technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input and at each output. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Smart POPS “Master" PDU can be connected to as many as three (with optional module) PRO2 Smart POPS “Link" PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.

Features

 

Network Monitoring

The PRO2 hot-swappable network card provides for HTTP(S), SSH, Telnet,SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
 
 

Hot-Swap Network Card

Network access is ensured when power is lost to the Master unit with backup power provided by the primary link unit.
 
 

Star Multi-Linking

PRO2 provides the ability to link up to four power circuits using one IP address. Primary link provides backup power to network card.
 
 

Temperature/ Humidity Monitoring

PRO2 Master and Link units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications.
 
 

Auto-Flip Current Display

Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets.
 
 

Per-Inlet Power Sensing

Meets ANSI C12.1 for billing-grade accuracy of Current per phase. PIPS includes voltage, active power, apparent power, power factor, and energy.
 
 

Per-Outlet Power Sensing

Meets ANSI C12.1 for billing-grade accuracy of Current per phase. POPS includes voltage, active power, apparent power, power factor, and energy.
 
 

Branch Current Monitoring

PRO2 monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.
 
 

Branch Circuit Protection

PRO2 meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses.
 
 

High Retention Locking Outlets

PRO2 receptacles have high retention and are compatible with P-Lock type power cords.
 
 

Color Identification

Choose from six colors to designate circuits for rack PDUs in the data center. Color options include Blue, Red, Green, White, Yellow, and Black.
 

Specifications

Specifications

  • Family Specifications
  • Branch Monitoring Current (A)
  • Branch Overcurrent Protection 5 kAIC
  • Branch Overcurrent Protection Type Circuit Breaker: 2-pole
  • Dual Input No
  • High Retention Outlets Yes
  • Input Current Display Auto-Orient
  • Input Monitoring PIPS
  • Locking Outlets Yes
  • Max Operating Temperature 60 °C
  • Fast Movers No
  • Mounting 0U Vertical
  • Outlet Monitoring POPS
  • PDU Platform
  • Power Pivot Input No
  • Product Height (inch) 69.0
  • Product Height (mm) 1753
  • Product Max Depth (inch) 3.5
  • Product Max Depth (mm) 89
  • Product Nominal Depth (inch) 3.5
  • Product Nominal Depth (mm) 89
  • Product Width (inch) 1.75
  • Product Width (mm) 45
  • Product Specifications
  • Input Power Capacity (kW) 5.7
  • Input Plug Type NEMA L21-20P
  • Input Current (A) 20
  • Input Current Rated (A) 16
  • Input Nominal Voltage (V) 208
  • Input Phase 3-Phase Wye (L-L)
  • Input Cord Location Bottom/Front
  • Outlet Form Factor Conventional
  • Total Outlets 24
  • IEC C13 Count 18
  • IEC C19 Count 6
  • Utility Outlet 1