Call NOW for quantity and project pricing

Please note the upcoming holiday schedule!

Rosh Hashanah October 3 - 5. Orders placed after 1 pm on October 2 will not be processed until Monday October 7th.

Sukkot: October 17 - October 26. Orders placed after 1 pm on October 16 will not be processed until Monday October 28th.

Rack Power Distribution Units (PDUs) Rack PDU PX3-5041V-F5M5
  • Guaranteed Satisfaction
  • Easy Returns
  • Authorized Reseller
  • Best Practice
$757.00

Order Now to ship Tomorrow

OR
Manufacturer Part Number:
PX3-5041V-F5M5
Sku:
9039868
Monitored and switched rack power distribution unit (0U [vertical], 1.4kVA, 4 outlets). INPUT: 120v, 15a - NEMA 5-15P plug (2P3W); OUTPUT: 1@ C13, 3@ 5-20R outlets; on 1@ 1-pole, 20a Overcurrent Protectors; FEATURES: Billing-Grade (+/- 1%) Energy Metering [kW, kVA, V, A, Power Factor] - per inlet, per breaker/fuse, per outlet; Remote Outlet Switching (Bi-State Latching Relays); Color, matrix LCD display : Voltage, current, or active power (per line, per breaker, or per receptacle / outlet); Alarms; Configuration information (name, ratings, IP / Networking information). Auto-flip orientation; Field-Replaceable, hot-swappable network module with 536MHz processor, 16MB SPI Flash, and 64MB DDR2 RAM; Gigabit(10/100/1000) Ethernet port. Secondary, redundant Ethernet port. Redundant power sharing between network modules.Remote network monitoring via HTML, JSON-RPC, SSH, Telnet, MODBUS/TCP, and SNMPv3. Environmental monitoring [temp/humidity] capable ñ up to 32 sensors. Individual outlet numbers labeled on chassis. Automated deployment via TFTP, DHCP/PXE, SSH(CLI), or USB Flash Drives. WiFi Capable. USB Webcam Capable. iPad/iPhone/Android App. Tri-color status LED per receptacle. Breaker metering and alarming (0V detection). Max Dimensions 52mm x 65mm x 515mm (2.1in x 2.6in x 20.3in). Max Weight 1.6 kg. Maximum ambient temperature 60C at full load.Vendor: Raritan; Part Number: PX3-5041V-F5M5

Features

 

120V, 1Φ, 1.4kVA, 12A

 
 

Securelock

 
 

Residual Current Monitoring

 
 

Removable Controller

 

Specifications

Specifications

  • Energy Metering Voltage (V), Current (A), Active Power (kW), Real Power (kVA), Energy (kWh), Power Factor
  • Metering Accuracy ISO/IEC 62053-21 1%
  • Remote Outlet Switching Yes
  • Metering per input line Yes for all models
  • Metering per Branch Circuit Breaker Yes
  • Environmental Sensor Ready Yes
  • Compatible Sensors Temperature, Humidity, Air Flow, Differential Pressure, Water Leak, and Contact Closure.
  • Cascading Yes, Max 16 PDUs can be daisy chained using a USB or Ethernet connection.
  • Networking 10/100 BaseT Ethernet.
  • Onboard Display Color, matrix LCD display : Voltage, current, or active power (per line, per breaker, or per receptacle / outlet); Alarms; Configuration information (name, ratings, IP / Networking information). Auto-flip orientation
  • Input Plug NEMA 5-15P (2P3W)
  • Nominal Voltage 120V
  • Maximum Input Current 15A
  • Rated Input Current 12A
  • Power Capacity 1.4kVA
  • Cord Length 3m
  • Nominal Voltage 120V
  • Receptacles (Output Connections) (1) IEC320 C13
  • Overload Protection (1) LEGBXA6-20
  • Dimensions (WxDxH) 2.1in x 2.6in x 20.3in; 52mm x 65mm x 515mm
  • Unit Weight 1.6 kg
  • Shipping Weight 3.1 kg
  • Shipping Dimensions 260mm x 123mm x 761mm
  • Mounting G2-RACK-FOR-ZU
  • Operating Temperature/Environment 60 C
  • Operating Relative Humidity 85%
  • Operating Elevation 0-10000ft
  • Regulatory Approvals UL
  • Warranty Standard 2 years manufacturer warranty
  • URL
 
  Loading...