Call NOW for quantity and project pricing

Please note the upcoming holiday schedule!

Rosh Hashanah October 3 - 5. Orders placed after 1 pm on October 2 will not be processed until Monday October 7th.

Sukkot: October 17 - October 26. Orders placed after 1 pm on October 16 will not be processed until Monday October 28th.

Rack Power Distribution Units (PDUs) Rack PDU PX2-5464-G1
  • Guaranteed Satisfaction
  • Easy Returns
  • Authorized Reseller
  • Best Practice
$1,229.18

Order Now to ship Tomorrow

OR
Manufacturer Part Number:
PX2-5464-G1
Sku:
12407534
Monitored and switched rack power distribution unit (0U [vertical], 5kVA, 20 outlets). INPUT: 208v, 30a - NEMA L6-30P plug (2P3W); OUTPUT: 16@ C13, 4@ C19 outlets; on 2@ 2-pole, 20a Overcurrent Protectors; FEATURES: Billing-Grade (+/- 1%) Energy Metering [kW, kVA, V, A, Power Factor] - per inlet, per breaker/fuse, per outlet; Remote Outlet Switching (Normally-Open Relays); 3-digit LED user-selectable display (voltage, current, or active power : per line, per breaker or per receptacle / outlet). Local display of alarms and configuration information(name, ratings, IP/Networking); Onboard embedded processor with minimum 400MHz clock speed, 16MB NOR Flash, and 64MB SDRAM; Remote network monitoring via HTML, JSON-RPC, SSH, Telnet, MODBUS/TCP, and SNMPv3. Environmental monitoring [temp/humidity] capable ñ up to 32 sensors. Individual outlet numbers labeled on chassis. Automated deployment via TFTP, DHCP/PXE, SSH(CLI), or USB Flash Drives. WiFi Capable. USB Webcam Capable. iPad/iPhone/Android App. Tri-color status LED per receptacle. Breaker metering and alarming (0V detection). Max Dimensions 52mm x 65mm x 1539mm (2.1in x 2.6in x 60.6in). Max Weight 5.6 kg. Maximum ambient temperature 60C at full load.Vendor: Raritan; Part Number: PX2-5464-G1

Features

 

208V, 1Φ, 5kVA, 24A

 
 

Securelock

 

Specifications

Specifications

  • Energy Metering Voltage (V), Current (A), Active Power (kW), Real Power (kVA), Energy (kWh), Power Factor
  • Metering Accuracy ISO/IEC 62053-21 1%
  • Remote Outlet Switching Yes
  • Metering per input line Yes for all models
  • Metering per Branch Circuit Breaker Yes
  • Environmental Sensor Ready Yes
  • Compatible Sensors Temperature, Humidity, Air Flow, Differential Pressure, Water Leak, and Contact Closure.
  • Cascading Yes, Max 16 PDUs can be daisy chained using a USB connection. Note: Firmware version 3.3.10 or above is required.
  • Networking 10/100 BaseT Ethernet.
  • Onboard Display 3-digit LED user-selectable display (voltage, current, or active power : per line, per breaker or per receptacle / outlet). Auto-flip orientation
  • Input Plug NEMA L6-30P (2P3W)
  • Nominal Voltage 208V
  • Maximum Input Current 30A
  • Rated Input Current 24A
  • Power Capacity 5kVA
  • Cord Length 3m
  • Nominal Voltage 208V
  • Receptacles (Output Connections) (16) IEC320 C13
  • Overload Protection (2) LEGBX66-20
  • Dimensions (WxDxH) 2.1in x 2.6in x 60.6in; 52mm x 65mm x 1539mm
  • Unit Weight 5.6 kg
  • Shipping Weight 7.8 kg
  • Shipping Dimensions 280mm x 115mm x 1655mm
  • Mounting G2-RACK-FOR-ZU
  • Operating Temperature/Environment 60 C
  • Operating Relative Humidity 85%
  • Operating Elevation 0-10000ft
  • Regulatory Approvals UL
  • Warranty Standard 2 years manufacturer warranty
  • URL
 
  Loading...