InRow RD, 600mm Air Cooled, 200-240V, 50/60Hz
  • Guaranteed Satisfaction
  • Easy Returns
  • Authorized Reseller
  • Best Practice
$16,750.00

Order Now to ship Tomorrow

Free Ground Shipping

OR
Manufacturer Part Number:
ACRD600
Sku:
31234181

Features

 

Rack inlet temperature control

Reduces the risk of hot spots at the rack level

 
 

Variable speed fans

Variable speed fans reduce energy consumption during off-peak cooling periods.

 
 

Active Airflow Control

Monitors and actively adjust cooling unit airflow in containment systems, while providing visibility to effective cooling to critical IT equipment.

 
 

Head pressure control

Modulates refrigerant head pressure to protect from coil freeze.

 
 

High Sensible-to-Total Cooling Ratio

Achieved by careful sizing of heat exchanger coils.

 
 

Temperature Display

Monitors and displays temperature to prevent overheating.

 
 

Minimizes Air Mixing

Delivers cool, conditioned air directly to the inlet of IT equipment.

 
 

Building management system integration

Send alarms and data points allowing you to manage critical building infrastructure from a single system.

 
 

Capacity Control

Cooling system will operate from 0 - 100% of the rated capacity to maintain rack inlet temperatures and reduce operational costs at varying heat loads.

 
 

Efficiency

Increases the capacity of the air conditioner by supplying a warmer return air temperature.

 
 

Predictable cooling

Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.

 
 

Programmable input/output contacts

Allows device contacts to be connected to the air conditioner and mapped to customer outputs or system alarms.

 
 

Modular strategy

Modular design of the mechanical and control systems allow for gradual build-up of the cooling infrastructure to match the cooling demand of the facility. This greatly reduces CAPEX expeditures and provides deferred investment throughout the life of the facility.

 
 

Flexibility

Support for varying aisle widths, rack heights, rack depths, and single rows. Supports hot and cold aisle containment

 
 

Rear containment

Ensures server exhaust air is returned to the InRow cooling units for maximum cooling predictability.

 
 

Horizontal airflow pattern

Removes heat close to the source of generation in the hot aisle and distributes cold air to the front of the racks in the cold aisle.

 
 

Field replaceable components

Fans and electronics module can be readily replaced without uninstalling the unit.

 
 

Hardwire capable

For installations where hard wiring is required or prefered.

 
 

Active response controls

Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.

 
 

Real-Time Capacity Monitoring

Real-time display of current and available cooling.

 
 

Real-Time capacity monitoring

Real-time display of current and available cooling.

 
 

Containment system compatible

The unit can be combined with a Rack or Hot Aisle Containment System to eliminate hot air mixing and maximize cooling efficiency

 
 

Active response control

Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.

 
 

Rack Inlet Temperature Control

Reduces the risk of hot spots at the rack level

 
 

Scaleable densities

Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.

 
 

Small Footprint

Efficient use of space with a small footprint provides the ability for the unit to be placed in a corner or even installed into a partitioned space.

 
 

Electronic expansion valve

Refrigerant flow optimization at any load and temperature conditions. Continuous indirect refrigerant charge monitoring

 
 

Ease of Use

Simplifies future planning by allowing side to side equipment to be placed anywhere in the data center.

 
 

Modular design

Modular design provides scalable solutions to add cooling as demand increases.

 
 

Fan guards

A safety measure that provides protection from the fan opening by covering the inlet.

 
 

Fault-tolerant fan system

In the event of a fan failure, the remaining fan(s) will continue to operate.

 
 

Casters

Provides flexibility to move the unit to wherever cooling is required.

 
 

Easy to install

Innovative design allows for fast, easy installation by almost anybody.

 
 

Local area network

Creates a shared control between all the available resources for maximum energy efficiency and controlled management of the group during emergency situations

 
 

Air filtration

Removes dirt and other particulates from the intake air for cleaner supply air.

 
 

Front service access

The system has full service, front access for routine servicing of components. Front access also narrows the footprint of the system making it possible for units to be placed side by side.

 
 

Architecturally neutral

Unobtrusive design and coloring, blends in with the surroundings.

 
 

Network interface

Provides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.

 
 

Row-based architecture

Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.

 
 

Easy service access

Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.

 
 

In-Row architecture

Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.

 
 

Green Refrigerant

Environmentally friendly refrigerant that can offer LEED points.

 
 

Touch-screen GUI

Enables easy configuration, full monitoring, and event logging

 
 

Scalable Design

Modular design provides scalable solutions to add cooling as demand increases.

 
 

Direct drive motors

Stress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.

 
 

Electronically Commutated Fans

Provide the highest efficiency and reduce total power consumption by matching the airflow requirements to the heat load of the data center.

 
 

Predictive failure notification

Maximizes system availability by providing early warning of required fan or filter replacement.

 
 

Enclosure system compatible

Specifically designed to work with Netshelter Enclosures.

 
 

Operational efficiency

Warmer entering air temperatures reduce both the required amount of humidification and the demand for costly reheat.

 
 

Increased capacity

Higher rate of heat removal allows more equipment to be installed in each rack.

 
 

Continuous current monitoring

Permits a continuous monitoring of the compressor’s absorbed current to signal possible discrepancies with the default values (Optional).

 
 

Microprocessor controller

Utilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display

 

Specifications

Specifications

  • Nominal Input Voltage 200V 3PH , 208V 3PH
  • Input frequency 50/60 Hz
  • Input Connections Hard Wire 4-wire (3PH + G)
  • Power Feeds 1.0
  • Input Power 14600.0Watts
  • Maximum Overcurrent Protection 80.0A
  • Minimum Circuit Amp Capacity 52.0
  • Control panel Multi-function LCD status and control console
  • Audible Alarm Audible and visible alarms prioritized by severity
  • Maximum Height 78.39inches (1991mm ,199.1CM )
  • Maximum Width 23.62inches (600mm ,60.0CM )
  • Maximum Depth 42.13inches (1070mm ,107.0CM )
  • Rack Height 42U
  • Net Weight 886.26lbs. (402.0KG )
  • Shipping weight 985.47lbs. (447.0KG )
  • Shipping Height 85.29inches (2166mm ,216.6CM )
  • Shipping Width 33.47inches (850mm ,85.0CM )
  • Shipping Depth 44.75inches (1137mm ,113.7CM )
  • Color Black
  • Units per Pallet 1.0
  • Operating Temperature -4 - 122 °F (-20 - 50 °C )
  • Operating Relative Humidity 5 - 95 %
  • Operating Elevation 0-10000ft (0-3000meters )
  • Audible noise at 1 meter from surface of unit 84.0dBA
  • Approvals cUL Listed, UL Listed
  • Standard warranty 1 year (parts only), 1 year on-site repair or replace with factory authorized Start-Up
  • Air Discharge Patterns Horizontal
  • Air Flow 4000.0CFM (1887.78lps )
  • Amp Draw In-Rush 30.0A
  • Compressor Type Scroll
  • Condensate Pump Capacity 32.0gal/hour (0.034lps )
  • Intake Air Rear Return
  • Return Diameter 0.75inches (19.0mm )
  • Supply Diameter 0.75inches (19.0mm )