PB Busway Tap Off Unit, 1x2 Pole 3 Wire 30A, L3-L1, 1 Drop cord, 3ft, L6-30, 208V
PB Busway Tap Off Unit, 1x2 Pole 3 Wire 30A, L3-L1, 1 Drop cord, 3ft, L6-30, 208V
Features
PBP4A12L630CAF Features
PB Busway Tap Off Unit, 1x2 Pole 3 Wire 30A, L3-L1, 1 Drop cord, 3ft, L6-30, 208V
Factory-assembled and tested, the tap off units house standard circuit breakers and a pre-terminated cord set. No tools required for installation on any iBusway for Data Center busway straight section.
Includes: Installation guide
Toolless installation of tap off units
Install factory assembled and tested tap off units in under 10 minutes - no tools necessary.
Specifications
Specifications
- Availability
-
Eliminate cable clutter
Aesthetic busway straights and tap off units with standard-length cables streamline the power distribution solution, simplify cable management, and reduce the risk of human error during moves, adds, and changes.
-
Factory-assembled and tested units
Reduce installation time and effort, and eliminate wiring mistakes during installation, with preassembled units that snap together.
-
Improved power availability
Above-the-row busway system eliminates underfloor cable distribution and overloaded PDU panels while reducing the chance for human error when moving, adding, or changing critical branch circuits.
- Manageability
-
Enhanced connection-point visibility
Quickly identify and reconfigure critical branch circuits - Tap Off Units with standard-length cables simplify identification of the circuit that supports each IT load in the data center row.
-
Real-time power monitoring
Monitor data usage in real time remotely using a Web browser.
- Total Cost of Ownership
-
Overhead design
Installing the power distribution solution above the row frees valuable data center space for additional revenue-generating IT equipment.
-
Energy efficient
Copper bus bars reduce heat losses and lower cooling demand.
-
Superior reliability
Powerbus busway uses silver-plated copper bus conductors for the greatest electrical efficiency.
- Adaptability
-
Quick installation
The iBusway for Data Center solution uses bolted snap-fit hangers and plug-in joint connections, which simplify installation and eliminate the need for expensive special tools.
-
High density
With up to 20 plug-in openings every 10 feet, this high-density solution ensures convenient placement of tap off units above the IT racks they support and provides flexibility to meet future power demands.
- Output
-
Nominal Output Voltage
208V
-
Cord Length
3ft
(0.91meters)
-
Maximum Total Current Draw
30
-
Output Connections
(1)
NEMA L6-30R
(Battery Backup)
-
Input frequency
60 Hz
- Physical
-
Maximum Height
12.0inches
(305MM, 30.5CM)
-
Maximum Width
8.48inches
(215MM, 21.5CM)
-
Maximum Depth
5.5inches
(140MM, 14.0CM)
-
Net Weight
18.0lbs.
(8.18KG)
-
Shipping weight
26.9lbs.
(12.23KG)
-
Shipping Height
13.5inches
(343MM, 34.3CM)
-
Shipping Width
13.5inches
(343MM, 34.3CM)
-
Shipping Depth
31.5inches
(800MM, 80.0CM)
-
Color
Black
- Environmental
-
Operating Temperature
14 - 104 °F
(-10 - 40 °C)
-
Operating Relative Humidity
0 - 95 %
-
Operating Elevation
0-10000ft
(0-3000meters)
-
Storage Temperature
-30 - 70 °C
-
Storage Relative Humidity
0 - 95 %
-
Storage Elevation
0-15000ft
(0-4500meters)
- Conformance
-
Approvals
cUL Listed, CSA, UL Listed
-
Standard warranty
1 year (parts only)
- Sustainable Offer Status
-
RoHS
Compliant
-
REACH
REACH: Contains No SVHCs
-