Rack Power Distribution Units (PDUs) Rack PDU PX2-4521V-E2
  • Guaranteed Satisfaction
  • Easy Returns
  • Authorized Reseller
  • Best Practice
$1,639.18

Order Now to ship Tomorrow

OR
Manufacturer Part Number:
PX2-4521V-E2
Sku:
616917
UPC:
785813011855
Monitored rack power distribution unit (0U [vertical], 8.6kVA, 24 outlets). INPUT: 208v (3-phase DELTA), 30a - NEMA L15-30P plug (3P4W); OUTPUT: 24@ C13 Locking outlets; on 3@ 2-pole, 20a Overcurrent Protectors; FEATURES: Billing-Grade (+/- 1%) Energy Metering [kW, kVA, V, A, Power Factor] - per inlet, per breaker/fuse, per outlet; 3-digit LED user-selectable display (voltage, current, or active power : per line, per breaker or per receptacle / outlet). Local display of alarms and configuration information(name, ratings, IP/Networking); Onboard embedded processor with minimum 400MHz clock speed, 16MB NOR Flash, and 64MB SDRAM; Remote network monitoring via HTML, JSON-RPC, SSH, Telnet, MODBUS/TCP, and SNMPv3. Environmental monitoring [temp/humidity] capable ñ up to 32 sensors. Individual outlet numbers labeled on chassis. Automated deployment via TFTP, DHCP/PXE, SSH(CLI), or USB Flash Drives. WiFi Capable. USB Webcam Capable. iPad/iPhone/Android App. Tri-color status LED per receptacle. Breaker metering and alarming (0V detection). Max Dimensions 52mm x 71mm x 1780mm (2.1in x 2.8in x 70.1in). Max Weight 7 kg. Maximum ambient temperature 60C at full load.Vendor: Raritan; Part Number: PX2-4521V-E2

Features

 

208V, 3Φ Delta, 8.6kVA, 24A

 
 

IEC Locking

 

Specifications

Specifications

  • Energy Metering Voltage (V), Current (A), Active Power (kW), Real Power (kVA), Energy (kWh), Power Factor
  • Metering Accuracy ISO/IEC 62053-21 1%
  • Remote Outlet Switching No
  • Metering per input line Yes for all models
  • Metering per Branch Circuit Breaker Yes
  • Environmental Sensor Ready Yes
  • Compatible Sensors Temperature, Humidity, Air Flow, Differential Pressure, Water Leak, and Contact Closure.
  • Cascading Yes, Max 16 PDUs can be daisy chained using a USB connection. Note: Firmware version 3.3.10 or above is required.
  • Networking 10/100 BaseT Ethernet.
  • Onboard Display 3-digit LED user-selectable display (voltage, current, or active power : per line, per breaker or per receptacle / outlet). Auto-flip orientation
  • Input Plug NEMA L15-30P (3P4W)
  • Nominal Voltage 208V
  • Maximum Input Current 30A
  • Rated Input Current 24A
  • Power Capacity 8.6kVA
  • Cord Length 3m
  • Nominal Voltage 208V
  • Receptacles (Output Connections) (24) IEC320 C13 Locking
  • Overload Protection (3) LEGBX66-20
  • Dimensions (WxDxH) 2.1in x 2.8in x 70.1in; 52mm x 71mm x 1780mm
  • Unit Weight 7 kg
  • Shipping Weight 9.5 kg
  • Shipping Dimensions 280mm x 115mm x 2070mm
  • Mounting G2-RACK-FOR-ZU
  • Operating Temperature/Environment 60 C
  • Operating Relative Humidity 85%
  • Operating Elevation 0-10000ft
  • Regulatory Approvals UL
  • Warranty Standard 2 years manufacturer warranty
  • URL
 
  Loading...