Galaxy VX 625kVA, 400V, Start up 5x8
Highly efficient, scalable, 3-phase power protection with flexible operating modes and ECOnversion™ for large facilities, data centers, and business critical applications.
Includes: Installation guide, Start-Up Service
Specifications
Specifications
Key Features
Output power capacity625.0kWatts
/ 625.0kVA
Nominal Output Voltage400V 3PH
Nominal Input Voltage400V 3PH
Maximum Input Current1063.0A
Serviceability
Front-access servicingSimplifies installation and UPS maintenance while minimizing space requirements.
5x8 Start-up service includedRequired for full coverage of factory warranty
Multiple levels of serviceWith the option of packages or individual service components, our services are structured to allow you to pick and choose what you would like APC to do for you.
StruxureWare Data Center Expert compatibleEnables centralized management via StruxureWare Data Center Expert.
StruxureOn enabledSimplify maintenance and operation of your equipment through the use of vendor-neutral, cloud-based software and services.
Availability
Compatible with Schneider Electric's lithium ion battery solutionReduces system footprint and weight, cooling and maintenance requirements, and total cost of ownership; offers double the life of VRLA batteries; and improves backup storage predictability and manageability.
Click
here
for more details.
Internal backfeed protectionIncreases system defense from power anomalies.
Energy storage flexibilityConventional flooded and modular battery offer along with different charging modes allows tailoring to specific back-up requirements.
Parallel-redundant capablePower the connected equipment with multiple uninterruptible power supplies to increase system redundancy
Parallel-capacity capableIncreases total power capacity by using multiple uninterruptible power supplies simultaneously.
Total Cost of Ownership
ECO ModeOperating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
ECOnversion modeOperating mode that ensures ultra high efficiency while charging the batteries, conditioning the load power factor and ensuring a Class 1 output voltage regulation.
Robust operationNo power derating in kW up to 40 degrees C or 104 degrees F.
Wide input voltage rangeDesigned for harsh electrical environments to save battery life.
Input power factor correctionMinimizes installation costs by enabling the use of smaller generators and cabling.
Output
Max Configurable Power (Watts)625.0kWatts
/ 625.0kVA
Output Frequency (sync to mains)50 Hz, 60 Hz
Output Frequency (not synced)50Hz +/- 0.1% for 50Hz nominal
Other Output Voltages380, 415, 440
Load Crest Factor3 with THC <5%
TopologyDouble Conversion Online
Waveform typeSine wave
Overload Operation150% for 1 minute 125% for 10 minutes
Output Voltage THD< 2% linear load and <3% non-linear load
Input
Input frequency40 - 70 Hz
Input Total Harmonic DistortionLess than 3% for full load
Other Input Voltages380, 415, 440
Maximum Short Circuit Withstand (Icw)100.0kAmps
Batteries & Runtime
Battery typeNo internal battery - uses external battery system
Nominal Battery Voltage480V
End of Discharge Battery Voltage384 Vdc
EfficiencyView Efficiency Graph
Communications & Management
Control panel7" Touch Screen Display
Audible AlarmAudible and visible alarms prioritized by severity